On 11/01/17 15:51, Enric Balletbo i Serra wrote: > To follow iio guidelines Where possible we stick to the raw SI unit, so > specify meters for proximity. > > Signed-off-by: Enric Balletbo i Serra <enric.balletbo@xxxxxxxxxxxxx> Please remember to add a change log to later versions of patch sets. Saves reviewers who typically have the memory of goldfish (well I do anyway) having to read old emails to check what they found last time! This patch is fine on it's own. Effectively allows us to drop the custom attribute description in sysfs-bus-iio-proximit-as3935 as well. (Matt cc'd) Applied to the togreg branch of iio.git. Thanks, Jonathan > --- > Documentation/ABI/testing/sysfs-bus-iio | 3 ++- > 1 file changed, 2 insertions(+), 1 deletion(-) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index b8f220f..1bd8ed1 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -1245,7 +1245,8 @@ Description: > reflectivity of infrared or ultrasound emitted. > Often these sensors are unit less and as such conversion > to SI units is not possible. Higher proximity measurements > - indicate closer objects, and vice versa. > + indicate closer objects, and vice versa. Units after > + application of scale and offset are meters. > > What: /sys/.../iio:deviceX/in_illuminance_input > What: /sys/.../iio:deviceX/in_illuminance_raw > -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html