On Mon, 2016-11-14 at 02:09 +0000, Song Hongyan wrote: > When user tried to read some fields like hysteresis from IIO sysfs on > some > systems, it fails. The reason is that this field is a byte field and > caller > of sensor_hub_get_feature() passes a buffer of 4 bytes. Here the > function > sensor_hub_get_feature() copies the single byte from the report to > the > caller buffer and returns "1" as the number of bytes copied. Is the following sentence accurate? > So caller > can use the return value, which is actually not right. Caller could have used a single byte from the result buffer as this is valid data ignoring other bytes. > Since this is done by multiple callers, if we change the > sensor_hub_get_feature() can make sure the caller buffer is > initialized > with 0s then we don't need to change all functions. > > Signed-off-by: Song Hongyan <hongyan.song@xxxxxxxxx> > --- > drivers/hid/hid-sensor-hub.c | 1 + > 1 file changed, 1 insertion(+) > > diff --git a/drivers/hid/hid-sensor-hub.c b/drivers/hid/hid-sensor- > hub.c > index 658a607..b74d954 100644 > --- a/drivers/hid/hid-sensor-hub.c > +++ b/drivers/hid/hid-sensor-hub.c > @@ -252,6 +252,7 @@ int sensor_hub_get_feature(struct > hid_sensor_hub_device *hsdev, u32 report_id, > int report_size; > int ret = 0; > > + memset(buffer, 0, buffer_size); > mutex_lock(&data->mutex); > report = sensor_hub_report(report_id, hsdev->hdev, > HID_FEATURE_REPORT); > if (!report || (field_index >= report->maxfield) ||��.n��������+%������w��{.n�����{��(��)��jg��������ݢj����G�������j:+v���w�m������w�������h�����٥