According to the datasheet, the resolusion of temperature sensor is -5.35 counts/C. Temperature ADC is 472 counts at 25C. (https://www.sparkfun.com/datasheets/Sensors/Pressure/MPL115A1.pdf NOTE: This is older revision, but this information is removed from the latest datasheet from nxp somehow) Temp [C] = (Tadc - 472) / -5.35 + 25 = (Tadc - 605.750000) * -0.186915888 So the correct offset is -605.750000. Signed-off-by: Akinobu Mita <akinobu.mita@xxxxxxxxx> Cc: Jonathan Cameron <jic23@xxxxxxxxxx> Cc: Hartmut Knaack <knaack.h@xxxxxx> Cc: Lars-Peter Clausen <lars@xxxxxxxxxx> Cc: Peter Meerwald <pmeerw@xxxxxxxxxx> Cc: linux-iio@xxxxxxxxxxxxxxx --- drivers/iio/pressure/mpl115.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/iio/pressure/mpl115.c b/drivers/iio/pressure/mpl115.c index 138344c..73f2f0c 100644 --- a/drivers/iio/pressure/mpl115.c +++ b/drivers/iio/pressure/mpl115.c @@ -118,7 +118,7 @@ static int mpl115_read_raw(struct iio_dev *indio_dev, *val = ret >> 6; return IIO_VAL_INT; case IIO_CHAN_INFO_OFFSET: - *val = 605; + *val = -605; *val2 = 750000; return IIO_VAL_INT_PLUS_MICRO; case IIO_CHAN_INFO_SCALE: -- 2.5.0 -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html