On 12/09/14 00:15, Jacob Pan wrote: > Add documentation for input current raw reading and scale. > > Signed-off-by: Jacob Pan <jacob.jun.pan@xxxxxxxxxxxxxxx> The content is fine, but please look at how the other types are handled. The raw attribute is described along with the units etc in it's own section, but the _scale attribute just gets lumped in with the equivalent for all the other channel types. Thanks, Jonathan > --- > Documentation/ABI/testing/sysfs-bus-iio | 8 ++++++++ > 1 file changed, 8 insertions(+) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index d760b02..3c76bd8 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -1028,3 +1028,11 @@ Contact: linux-iio@xxxxxxxxxxxxxxx > Description: > Raw value of rotation from true/magnetic north measured with > or without compensation from tilt sensors. > + > +What: /sys/bus/iio/devices/iio:deviceX/in_currentX_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_currentX_scale > +KernelVersion: 3.18 > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + Raw current measurement from channel X. Units after application of > + scale and offset are milliamps. > -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html