The userspace interface for acceleration sensors is documented as using m/s^2 units [Documentation/ABI/testing/sysfs-bus-iio] The fullscale raw value for the mma8452 (-2048) corresponds to -2G, -4G or -8G depending on the seleted mode. The scale table was converting to G rather than m/s^2. Change the scaling table to match the documented interface. Signed-off-by: Martin Fuzzey <mfuzzey@xxxxxxxxxxx> --- drivers/iio/accel/mma8452.c | 7 ++++++- 1 file changed, 6 insertions(+), 1 deletion(-) diff --git a/drivers/iio/accel/mma8452.c b/drivers/iio/accel/mma8452.c index 17aeea1..61eba5a 100644 --- a/drivers/iio/accel/mma8452.c +++ b/drivers/iio/accel/mma8452.c @@ -111,8 +111,13 @@ static const int mma8452_samp_freq[8][2] = { {6, 250000}, {1, 560000} }; +/* Hardware has fullscale of -2G, -4G, -8G corresponding to raw value -2048 + * The userspace interface uses m/s^2 and we declare micro units + * So scale factor is given by: + * g * N * 1000000 / 2048 for N = 2, 4, 8 and g=9.80665 + */ static const int mma8452_scales[3][2] = { - {0, 977}, {0, 1953}, {0, 3906} + {0, 9577}, {0, 19154}, {0, 38307} }; static ssize_t mma8452_show_samp_freq_avail(struct device *dev, -- To unsubscribe from this list: send the line "unsubscribe linux-iio" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html