On 12/11/2010 03:37 PM, Igor Plyatov wrote:
The AT91SAM9 microcontrollers with master clock higher then 105 MHz
and PIO0, have overflow of the NCS_RD_PULSE value in the MSB. This
lead to "NCS_RD_PULSE" pulse longer then "NRD_CYCLE" pulse and driver
does not detect ATA device.

Signed-off-by: Igor Plyatov<plyatov@xxxxxxxxx>

Thanks, queued (absent further comments...)


--