Re: MD/RAID time out writing superblock

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Tue, 01 Sep 2009 09:47:31 -0400, Ric Wheeler <rwheeler@xxxxxxxxxx>
wrote:
>>>> Mine errored out again with exactly the same symptoms, this time after
>>>> only
>>>> few days and with the "tunable" set to 2 sec. I got a warranty
>>>> replacement
>>>> but haven't shipped this one yet. Let me know if you want it.
>>> ..
>>>
>>> Not me.  But perhaps Tejun ?
>>
>> I think you're much more qualified than me on the subject. :-)
>>
>> Anyone else?  Ric, are you interested with playing the drive?
> 
> No thanks....
> 
> I would suggest that Andrei install the new drive and watch it for a few
> days to 
> make sure that it does not fail in the same way. If it does, you might
want
> to look at the power supply/cables/etc?

The drive is the second member of RAID1 array, as far as I understand, both
drives should be experiencing very similar access patterns, and they are
the same model with the same firmware, and manufactured on the same day,
but only one of them showed these symptoms, so there must be something
"special" about it.
By now I think that MD made the right "decision" failing the drive and
removing it from the array, so I guess let's leave it at that.

Andrei.
--
To unsubscribe from this list: send the line "unsubscribe linux-ide" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux Filesystems]     [Linux SCSI]     [Linux RAID]     [Git]     [Kernel Newbies]     [Linux Newbie]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Samba]     [Device Mapper]