On 08/09/2009 04:36 AM, Miah Gregory wrote:
Hi, One of my servers has started to log slightly odd errors following one of the software RAID arrays having been degraded due to an error on sdb. ata4.00: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 frozen ata4.00: cmd ea/00:00:00:00:00/00:00:00:00:00/a0 tag 0 res 40/00:00:09:4f:c2/00:00:00:00:00/00 Emask 0x4 (timeout) ata4.00: status: { DRDY } ata4: hard resetting link ata4: SATA link up 3.0 Gbps (SStatus 123 SControl 300) ata4.00: configured for UDMA/133 ata4: EH complete sd 3:0:0:0: [sdb] 976773168 512-byte hardware sectors: (500 GB/465 GiB) end_request: I/O error, dev sdb, sector 976767834
This is a cache flush request that's timing out, the others are SMART requests. Random timeouts are rather hard to diagnose but can often be caused by hardware issues. You mentioned you have 4 drives in the machine, SATA can be rather sensitive to power issues and it's possible the power supply can't handle peak demands from all 4 drives simultaneously. Might be something to look into first.
-- To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html