Hello, Andrew Ryder wrote: > Yes the issue is still there. I have also tried it with 2.6.24-rc6-git4. > > BootLog1.txt > 2.6.24-rc6-git4: machine booting up, drive array on before machine is > powered on, drive array is configured as one large disk (RAID-1). > > Bootlog2.txt > Same kernel as #1, system has been up for a day or two, drive array was > turned off after the boot failure in #1 and I turned it on again to see > if it made any difference. > > Bootlog3.txt > Booted system, drive array already on, kernel 2.6.24-rc6 and the drive > array was configured as one large disk (RAID-1). > > Bootlog4.txt > Same as #3, but drive array was configured in JBOD mode. > > If you have any not too dangerous fixes you want to test, let me know. I > can give them a try on my hardware here. Hmmmm... This is weird. I have two reports on addonics reporting the same problem now. In boot log 1 and 3, the first fan-out port (ata1.00) is down while on 2 and 4, the link is up. Was there any hardware configuration change? 4726 is known to malfunction if the first port isn't occupied. Thanks. -- tejun - To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html