On 4/17/07, Tejun Heo <htejun@xxxxxxxxx> wrote:
Certainly not. Can you post the result of 'smartctl -d ata -a /dev/sdX'?
Here is smartctl -d ata -a /dev/sda for the same HD that presented the previous log messages: ----------------------------------------------------------------------------------------------------- smartctl version 5.36 [i686-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: SAMSUNG HD400LJ Serial Number: S0H2J1UL602108 Firmware Version: ZZ100-14 User Capacity: 400,088,457,216 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a Local Time is: Tue Apr 17 14:20:20 2007 BRT ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (7576) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 129) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 100 100 015 Pre-fail Always - 7936 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 8 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 253 253 000 Old_age Always - 16 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 8 190 Unknown_Attribute 0x0022 061 060 000 Old_age Always - 39 194 Temperature_Celsius 0x0022 121 118 000 Old_age Always - 39 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 507637 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 202 TA_Increase_Count 0x0032 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1 SMART Selective self-test log data structure revision number 0 Warning: ATA Specification requires selective self-test log data structure revision number = 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. ----------------------------------------------------------------------------------------------------- I bought a new SATA board this morning. lspci -v: ----------------------------------------------------------------------------------------------------- 01:07.0 RAID bus controller: VIA Technologies, Inc. VT6421 IDE RAID Controller (rev 50) Subsystem: VIA Technologies, Inc. VT6421 IDE RAID Controller Flags: bus master, medium devsel, latency 32, IRQ 16 I/O ports at c000 [size=16] I/O ports at c400 [size=16] I/O ports at c800 [size=16] I/O ports at cc00 [size=16] I/O ports at d000 [size=32] I/O ports at d400 [size=256] [virtual] Expansion ROM at 30040000 [disabled] [size=64K] Capabilities: [e0] Power Management version 2 ----------------------------------------------------------------------------------------------------- This is the SATA board running now. Everything else is exactly the same. I got no syslog messages after rsyncing 255GB. I believe the smartctl output is still valid despite having other SATA board. Please let me know if there is anything else I can do to help debug this issue. I can put the ULi M5281/M5283 back for tests. Thanks for your attention, Rodrigo Severo - To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html