Re: ICH6-M libata disk timeouts in 2.6.19 (except with small queue depth)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Mike Accetta wrote:
> The distinguishing factor appears to be the queue depth (4 works, 5
> and various values up to and including 31 fail) not the kernel version.
> I am going to try running with the queue depth clamped at 4 to see if
> this consistently masks the problem.  I may also try some more experiments
> if I have the time, like instrumenting what command was issued right
> before the group that all time out or increasing the SCSI timeout,
> in order to get some more insight into what is going on at the time of
> the failure.

Please report the result of 'hdparm -I /dev/sdX' where sdX is the
problematic disk.  Quite a few drives have problem with NCQ and we have
to blacklist them.

Thanks.

-- 
tejun
-
To unsubscribe from this list: send the line "unsubscribe linux-ide" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html