On Mon, 2023-11-27 at 15:08 +0700, Quan Nguyen wrote: > > On 27/11/2023 14:04, Cosmo Chou wrote: > > Andrew Jeffery <andrew@xxxxxxxxxxxxxxxxxxxx> wrote on Mon, 2023-11-27 > > at 11:23 AM: > > > > > > On Mon, 2023-11-20 at 17:17 +0800, Cosmo Chou wrote: > > > > commit 2be6b47211e1 ("i2c: aspeed: Acknowledge most interrupts early > > > > in interrupt handler") moved most interrupt acknowledgments to the > > > > start of the interrupt handler to avoid race conditions. However, > > > > slave Tx ack status shouldn't be cleared before SLAVE_READ_PROCESSED > > > > is handled. > > > > > > > > Acknowledge Tx ack status after handling SLAVE_READ_PROCESSED to fix > > > > the problem that the next byte is not sent correctly. > > > > > > What does this mean in practice? Can you provide more details? It > > > sounds like you've seen concrete problems and it would be nice to > > > capture what it was that occurred. > > > > > > Andrew > > > > For a normal slave transaction, a master attempts to read out N bytes > > from BMC: (BMC addr: 0x20) > > [S] [21] [A] [1st_B] [1_ack] [2nd_B] [2_ack] ... [Nth_B] [N] [P] > > > > T1: when [21] [A]: Both INTR_SLAVE_MATCH and INTR_RX_DONE rise, > > INTR_RX_DONE is not cleared until BMC is ready to send the 1st_B: > > https://github.com/torvalds/linux/blob/master/drivers/i2c/busses/i2c-aspeed.c#L294 > > That is, BMC stretches the SCL until ready to send the 1st_B. > > > > T2: when [1_ack]: INTR_TX_ACK rises, but it's cleared at the start of > > the ISR, so that BMC does not stretch the SCL, the master continues > > to read 2nd_B before BMC is ready to send the 2nd_B. > > > > To fix this, do not clear INTR_TX_ACK until BMC is ready to send data: > > https://github.com/torvalds/linux/blob/master/drivers/i2c/busses/i2c-aspeed.c#L302 > > > > This looks like the same issue, but we chose to ack them late. Same with > INTR_RX_DONE. > > https://lore.kernel.org/all/20210616031046.2317-3-quan@xxxxxxxxxxxxxxxxxxxxxx/ >From a brief inspection I prefer the descriptions in your series Quan. Looks like we dropped the ball a bit there though on the review - can you resend your series based on 6.7-rc1 or so and Cc Cosmo? Cheers, Andrew