> -----Original Message----- > From: Krzysztof Adamski <krzysztof.adamski@xxxxxxxxx> > Sent: Wednesday, June 29, 2022 5:52 PM > To: Manikanta Guntupalli <manikanta.guntupalli@xxxxxxxxxx>; > michal.simek@xxxxxxxxxx; Simek, Michal <michal.simek@xxxxxxx>; linux- > arm-kernel@xxxxxxxxxxxxxxxxxxx; linux-i2c@xxxxxxxxxxxxxxx; linux- > kernel@xxxxxxxxxxxxxxx; git (AMD-Xilinx) <git@xxxxxxx> > Cc: Raviteja Narayanam <raviteja.narayanam@xxxxxxxxxx> > Subject: Re: [PATCH 02/12] i2c: xiic: Enter standard mode only for > 255 byte > read transfers > > CAUTION: This message has originated from an External Source. Please use > proper judgment and caution when opening attachments, clicking links, or > responding to this email. > > > Hi, > > W dniu 24.06.2022 o 14:05, Manikanta Guntupalli pisze: > > From: Raviteja Narayanam <raviteja.narayanam@xxxxxxxxxx> > > > > To maintain backward compatibility the default transfer mode is > > dynamic mode. Enter standard mode only when the size of read transfer > > is > 255 bytes. > > > > Signed-off-by: Raviteja Narayanam <raviteja.narayanam@xxxxxxxxxx> > > Signed-off-by: Manikanta Guntupalli <manikanta.guntupalli@xxxxxxxxxx> > > [...] > > I don't really understand why this patch isn't squashed into previous one. The > previous patch was only checking the first message which was wrong, this > one fixes that. We will fix in V2 Thanks, Manikanta.