śr., 23 paź 2019 o 10:22 Bibby Hsieh <bibby.hsieh@xxxxxxxxxxxx> napisał(a): > > Although in the most platforms, the power of eeprom and i2c > are alway on, some platforms disable the eeprom and i2c power > in order to meet low power request. > This patch add the pm_runtime ops to control power to support > all platforms. > > Changes since v5: > - remove has_supplies > > Changes since v4: > - add system sleep PM ops > - move regulator_bulk_disable before suspend() > - fixes error handling > > Changes since v3: > - remove redundant calling function > - change SIMPLE_DEV_PM_OPS to SET_RUNTIME_PM_OPS > - change supply name > > Changes since v2: > - rebase onto v5.4-rc1 > - pm_runtime_disable and regulator_bulk_disable at > err return in probe function > > Changes since v1: > - remove redundant code > - fixup coding style > > Signed-off-by: Bibby Hsieh <bibby.hsieh@xxxxxxxxxxxx> > --- > drivers/misc/eeprom/at24.c | 50 ++++++++++++++++++++++++++++++++++++++ > 1 file changed, 50 insertions(+) > > diff --git a/drivers/misc/eeprom/at24.c b/drivers/misc/eeprom/at24.c > index 2cccd82a3106..1332bba93d32 100644 > --- a/drivers/misc/eeprom/at24.c > +++ b/drivers/misc/eeprom/at24.c > @@ -22,6 +22,7 @@ > #include <linux/nvmem-provider.h> > #include <linux/regmap.h> > #include <linux/pm_runtime.h> > +#include <linux/regulator/consumer.h> > #include <linux/gpio/consumer.h> > > /* Address pointer is 16 bit. */ > @@ -67,6 +68,12 @@ > * which won't work on pure SMBus systems. > */ > > +static const char * const at24_supply_names[] = { > + "vcc", "i2c", > +}; > + > +#define AT24_NUM_SUPPLIES ARRAY_SIZE(at24_supply_names) > + > struct at24_client { > struct i2c_client *client; > struct regmap *regmap; > @@ -91,6 +98,7 @@ struct at24_data { > > struct gpio_desc *wp_gpio; > > + struct regulator_bulk_data supplies[AT24_NUM_SUPPLIES]; > /* > * Some chips tie up multiple I2C addresses; dummy devices reserve > * them for us, and we'll use them with SMBus calls. > @@ -662,6 +670,11 @@ static int at24_probe(struct i2c_client *client) > at24->client[0].client = client; > at24->client[0].regmap = regmap; > > + regulator_bulk_set_supply_names(at24->supplies, > + at24_supply_names, AT24_NUM_SUPPLIES); > + devm_regulator_bulk_get(&at24->client[0].client->dev, > + AT24_NUM_SUPPLIES, at24->supplies); You still need to check the return value here - this call can still fail for many reasons. > + > at24->wp_gpio = devm_gpiod_get_optional(dev, "wp", GPIOD_OUT_HIGH); > if (IS_ERR(at24->wp_gpio)) > return PTR_ERR(at24->wp_gpio); > @@ -701,6 +714,12 @@ static int at24_probe(struct i2c_client *client) > > i2c_set_clientdata(client, at24); > > + err = regulator_bulk_enable(AT24_NUM_SUPPLIES, at24->supplies); > + if (err) { > + dev_err(dev, "Failed to enable power regulators\n"); > + return err; > + } > + > /* enable runtime pm */ > pm_runtime_set_active(dev); > pm_runtime_enable(dev); > @@ -713,6 +732,8 @@ static int at24_probe(struct i2c_client *client) > pm_runtime_idle(dev); > if (err) { > pm_runtime_disable(dev); > + regulator_bulk_disable(AT24_NUM_SUPPLIES, > + at24->supplies); > return -ENODEV; > } > > @@ -725,15 +746,44 @@ static int at24_probe(struct i2c_client *client) > > static int at24_remove(struct i2c_client *client) > { > + struct at24_data *at24 = i2c_get_clientdata(client); > + > pm_runtime_disable(&client->dev); > + if (pm_runtime_status_suspended(&client->dev)) > + regulator_bulk_disable(AT24_NUM_SUPPLIES, at24->supplies); So you will now disable the regulators if they're already disabled in at24_suspend() but not disable them if they're not. This is clearly inverted. Bart > pm_runtime_set_suspended(&client->dev); > > return 0; > } > > +static int __maybe_unused at24_suspend(struct device *dev) > +{ > + struct i2c_client *client = to_i2c_client(dev); > + struct at24_data *at24 = i2c_get_clientdata(client); > + > + return regulator_bulk_disable(AT24_NUM_SUPPLIES, > + at24->supplies); > +} > + > +static int __maybe_unused at24_resume(struct device *dev) > +{ > + struct i2c_client *client = to_i2c_client(dev); > + struct at24_data *at24 = i2c_get_clientdata(client); > + > + return regulator_bulk_enable(AT24_NUM_SUPPLIES, > + at24->supplies); > +} > + > +static const struct dev_pm_ops at24_pm_ops = { > + SET_SYSTEM_SLEEP_PM_OPS(pm_runtime_force_suspend, > + pm_runtime_force_resume) > + SET_RUNTIME_PM_OPS(at24_suspend, at24_resume, NULL) > +}; > + > static struct i2c_driver at24_driver = { > .driver = { > .name = "at24", > + .pm = &at24_pm_ops, > .of_match_table = at24_of_match, > .acpi_match_table = ACPI_PTR(at24_acpi_ids), > }, > -- > 2.18.0 >