On Fri, Mar 2, 2018 at 2:11 AM, Wolfram Sang <wsa@xxxxxxxxxxxxx> wrote: > > On Tue, Feb 27, 2018 at 04:42:13PM +0100, Jan Glauber wrote: > > The error message: > > > > [Fri Feb 16 13:42:13 2018] i2c-thunderx 0000:01:09.4: unhandled state: 0 > > > > is mis-leading as state 0 (bus error) is not an unknown state. > > > > Return -EIO as before but avoid printing the message. Also rename > > STAT_ERROR to STATE_BUS_ERROR. > > > > Signed-off-by: Jan Glauber <jglauber@xxxxxxxxxx> > > Applied to for-current, thanks! Did you also pick up the i2c-xlp9xx patches for current? Similar set of issues there. Multiple people have now tested them and reported they resolve issues with IPMI SSIF on ThunderX2 platforms. Thanks, Phil P. -- Philip Pokorny, RHCE Chief Technology Officer PENGUIN COMPUTING, Inc www.penguincomputing.com Changing the world through technical innovation