On Tue, Jun 14, 2016 at 09:26:46PM +0100, Jon Hunter wrote: > Commit 497fbe24987b ("i2c: tegra: enable multi master mode for tegra210") > enables the Tegra I2C 'div_clk' for adapters using the multi-master mode > during the device probe. Although the probe error path was updated to > disable the clock on probe failure, there is one place after calling > tegra_i2c_init() where the clock will not be disabled on failure. Correct > the error path so that the 'div_clk' is disabled if calling > tegra_i2c_init() fails. > > Fixes: 497fbe24987b ("i2c: tegra: enable multi master mode for tegra210") > > Signed-off-by: Jon Hunter <jonathanh@xxxxxxxxxx> Applied to for-current, thanks!