On Wed, Feb 17, 2016 at 10:26:35AM +0100, Jean Delvare wrote: > The SB800 register reference guide says that the SMBus port selection > bits may not always be in register Smbus0En (0x2c) but could > alternatively be found in register Smbus0Sel (0x2e) depending on the > settings in register Smbus0SelEn (0x2f.) Add support for this > configuration. > > The "alternative" register is the only one working for the Bolton > (aka Hudson-2) chipset anyway. I do not have any documentation for > the "kerncz" chipset so we treat it the same as the Bolton for now. > > Signed-off-by: Jean Delvare <jdelvare@xxxxxxx> > Tested-by: Jean Delvare <jdelvare@xxxxxxx> > Tested-by: Christian Fetzer <fetzer.ch@xxxxxxxxx> > Reviewed-by: Mika Westerberg <mika.westerberg@xxxxxxxxxxxxxxx> > Cc: Wolfram Sang <wsa@xxxxxxxxxxxxx> Applied to for-next, thanks!