On Mon, Jan 20, 2014 at 05:43:43PM +0100, Romain Baeriswyl wrote: > This patch allows to set independantly SCL and SDA falling times. > The tLOW period is computed by taking into account the SCL falling time. > The tHIGH period is computed by taking into account the SDA falling time. > > For instance in case the margin on tLOW is considered too small, it can > be increased by increasing the SCL falling time which is by default set > at 300ns. > > The same applies for tHIGH period with the help of SDA falling time. > > Signed-off-by: Romain Baeriswyl <romainba@xxxxxxxxxx> > Reviewed-by: Christian Ruppert <christian.ruppert@xxxxxxxxxx> Applied to for-next, thanks!
Attachment:
signature.asc
Description: Digital signature