Re: [PATCH 2/2] hwmon: (max16065) Fix alarm attributes

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Sun, Jul 21, 2024 at 12:35:06PM -0700, Guenter Roeck wrote:
> Chips reporting overcurrent alarms report it in the second alarm register.

I can't understand the sentence.  Not sure whether it needs to be rephrased or
not.  s/overcurrent/overvoltage/.

> That means the second alarm register has to be read, even if the chip only
> supports 8 or fewer ADC channels.
> 
> MAX16067 and MAX16068 report undervoltage and overvoltage alarms in
> separate registers. Fold register contents together to report both with
> the existing alarm attribute. This requires actually storing the chip type
> in struct max16065_data. Rename the variable 'chip' to match the variable
> name used in the probe function.
> 
> Fixes: f5bae2642e3d ("hwmon: Driver for MAX16065 System Manager and compatibles")
> Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>

Reviewed-by: Tzung-Bi Shih <tzungbi@xxxxxxxxxx>