On Tue, Jun 11, 2024 at 11:36:26AM +0200, Amna Waseem wrote: > The INA230 has an Alert pin which is asserted when the alert > function selected in the Mask/Enable register exceeds the > value programmed into the Alert Limit register. Assertion is based > on the Alert Polarity Bit (APOL, bit 1 of the Mask/Enable register). > It is default set to value 0 i.e Normal (active-low open collector). > However, hardware can be designed in such a way that expects Alert pin > to become active high if a user-defined threshold in Alert limit > register has been exceeded. This patch adds a way to pass alert polarity > value to the driver via device tree. > > Signed-off-by: Amna Waseem <Amna.Waseem@xxxxxxxx> Applied. Guenter