On 8/31/2022 12:42 PM, Philipp Zabel wrote:
On Mi, 2022-08-31 at 12:23 +0300, Farber, Eliav wrote:
On 8/31/2022 11:23 AM, Philipp Zabel wrote:
> On Di, 2022-08-30 at 19:22 +0000, Eliav Farber wrote:
> > Add optional "moortec,ts-series" property to define the temperature
> > equation and coefficients that shall be used to convert the digital
> > output to value in milli-Celsius.
> > Supported series: 5 (default) and 6.
>
> Is this the difference between mr75xxx and mr76xxx series?
> If so, should be a compatible "moortec,mr76006" instead?
> If the temperature equation could be derived from the compatible, this
> property would not be necessary.
The PVT (Process, Voltage, Temperature) monitoring logic can be
constructed from many different sub-blocks:
*) CONTROLLER (mr75203) - controlling TS, PD and VM.
*) TS (mr74137) - for measuring temperature in ring.
*) PD (mr74139) - for measuring IO based transistors.
*) VM (mr74138) - for measuring voltage rails across the SoC.
*) Ring oscillators (mr76007/mr76008)
*) Pre-scalers (mr76006)
Besides mr75203 which is digital all other IPs are analog.
There is a single mr75203 and there can be several or none of the other
units.
Thank you for the explanation, I think this information would be nice
to have in a description in moortec,mr75203.yaml.
For v4 I added a new patch which adds this description in
moortec,mr75203.yaml:
description: |
A Moortec PVT (Process, Voltage, Temperature) monitoring logic design can
include many different units.
Such a design will usually consists of several Moortec's embedded
analog IPs,
and a single Moortec controller to configure and control the IPs.
Some of the Moortec's analog hard IPs that can be used in a design:
*) Temperature Sensor (TS) - used to monitor core temperature (e.g.
mr74137).
*) Voltage Monitor (VM) - used to monitor voltage levels (e.g. mr74138).
*) Process Detector (PD) - used to assess silicon speed (e.g. mr74139).
*) Delay Chain - ring oscillator connected to the PD, used to measure IO
based transistors (e.g. mr76008 ring oscillator at 1.1V, mr76007 ring
oscillator at 1.8V).
*) Pre Scaler - provides divide-by-X scaling of input voltage, which
can then
be presented for VM for measurement within its range (e.g. mr76006 -
divide by 2 pre-scaler).
TS, VM & PD also include a digital interface, which consists of
configuration
inputs and measurement outputs.
The mr75203 binding describes configuration for the controller unit,
but also
for some of the analog IPs.
--
Regards, Eliav