From: Slawomir Stepien <slawomir.stepien@xxxxxxxxx> Try to read the channel's temperature offset from device-tree. Having offset in device-tree node is not mandatory. The offset can only be set for remote channels. Signed-off-by: Slawomir Stepien <slawomir.stepien@xxxxxxxxx> --- Changes since v1: * Use the new function lm90_set_temp_offset. * Update the messages in dev_err() calls. drivers/hwmon/lm90.c | 16 ++++++++++++++++ 1 file changed, 16 insertions(+) diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c index ec885cb3ab92..9d878163a1f2 100644 --- a/drivers/hwmon/lm90.c +++ b/drivers/hwmon/lm90.c @@ -2666,6 +2666,7 @@ static int lm90_probe_channel_from_dt(struct i2c_client *client, struct lm90_data *data) { u32 id; + s32 val; int err; struct device *dev = &client->dev; @@ -2689,6 +2690,21 @@ static int lm90_probe_channel_from_dt(struct i2c_client *client, if (data->channel_label[id]) data->channel_config[id] |= HWMON_T_LABEL; + err = of_property_read_s32(child, "temperature-offset-millicelsius", &val); + if (!err) { + if (id == 0) { + dev_err(dev, "temperature-offset-millicelsius can't be set for internal channel\n"); + return -EINVAL; + } + + err = lm90_set_temp_offset(data, lm90_temp_offset_index[id], id, val); + if (err) { + dev_err(dev, "can't set temperature offset %d for channel %d (%d)\n", + val, id, err); + return err; + } + } + return 0; } -- 2.36.1