Hi Guenter, According to the NCT7802Y datasheet, the REG_VOLTAGE_LIMIT_LSB definition is wrong and leads to wrong threshold registers used. It should be : static const u8 REG_VOLTAGE_LIMIT_LSB[2][5] = { { 0x46, 0x00, 0x40, 0x42, 0x44 }, { 0x45, 0x00, 0x3f, 0x41, 0x43 }, }; With this definition, the right bit is set in "Voltage SMI Status Register @0x1e" for each threshold reached (using i2cget to check) But I'm unable to get any "ALARM" reported by the command "sensors" for VSEN1/2/3 = in2,in3,in4 because status for in0 is read before (unless I set "ignore in0" in sensors file). The problem is that status bits in "Voltage SMI Status Register @0x1e" are cleared when reading, and a read is done for each inX processed, so only the first inX has a chance to get its alarm bit set. For this problem I don't see how to fix this easily; just to let you know ... Best regards Gilles BULOZ Senior software(/hardware) engineer | R&D Kontron Modular Computers S.A.S.