[PATCH v2 4/7] fsnotify: skip unattached marks

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



After having gone through a ref-unref for the mark, dereferencing the group
(e.g. in fsnotify_compare_groups()) is wrong since the group may be
completely gone by that time.  So before continuing to traverse the mark
list, check if the mark is still attached.

This is done in the generic case, not just when we go through
fsnotify_prepare_user_wait()/fsnotify_finish_user_wait(), otherwise it
would introduce unnecessary complexity.  And it shouldn't hurt to skip
unattached marks anyway ("flags" is very likely in same cacheline as
neighbouring "ignored_mask", which is pulled in anyway).

Signed-off-by: Miklos Szeredi <mszeredi@xxxxxxxxxx>
Fixes: 9385a84d7e1f ("fsnotify: Pass fsnotify_iter_info into handle_event handler")
Cc: <stable@xxxxxxxxxxxxxxx> # v4.12
---
 fs/notify/fsnotify.c | 7 ++++++-
 1 file changed, 6 insertions(+), 1 deletion(-)

diff --git a/fs/notify/fsnotify.c b/fs/notify/fsnotify.c
index 48ec61f4c4d5..0ab6a7179e4d 100644
--- a/fs/notify/fsnotify.c
+++ b/fs/notify/fsnotify.c
@@ -328,12 +328,16 @@ int fsnotify(struct inode *to_tell, __u32 mask, const void *data, int data_is,
 			inode_mark = hlist_entry(srcu_dereference(inode_node, &fsnotify_mark_srcu),
 						 struct fsnotify_mark, obj_list);
 			inode_group = inode_mark->group;
+			if (!(inode_mark->flags & FSNOTIFY_MARK_FLAG_ATTACHED))
+				goto skip_inode;
 		}
 
 		if (vfsmount_node) {
 			vfsmount_mark = hlist_entry(srcu_dereference(vfsmount_node, &fsnotify_mark_srcu),
 						    struct fsnotify_mark, obj_list);
 			vfsmount_group = vfsmount_mark->group;
+			if (!(vfsmount_mark->flags & FSNOTIFY_MARK_FLAG_ATTACHED))
+				goto skip_vfsmount;
 		}
 
 		iter_info.inode_mark = inode_mark;
@@ -357,10 +361,11 @@ int fsnotify(struct inode *to_tell, __u32 mask, const void *data, int data_is,
 
 		if (ret && (mask & ALL_FSNOTIFY_PERM_EVENTS))
 			goto out;
-
+skip_inode:
 		if (inode_group)
 			inode_node = srcu_dereference(inode_node->next,
 						      &fsnotify_mark_srcu);
+skip_vfsmount:
 		if (vfsmount_group)
 			vfsmount_node = srcu_dereference(vfsmount_node->next,
 							 &fsnotify_mark_srcu);
-- 
2.5.5




[Index of Archives]     [Linux Ext4 Filesystem]     [Union Filesystem]     [Filesystem Testing]     [Ceph Users]     [Ecryptfs]     [AutoFS]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux Cachefs]     [Reiser Filesystem]     [Linux RAID]     [Samba]     [Device Mapper]     [CEPH Development]