w-thiel@xxxxxxx wrote: > On Sun, Dec 04, 2005 at 01:27:04PM +0100, Oliver Endriss wrote: > > ... > > > > I did some tests using > > BBC WS English;BBC WS:11131:vC34:S13.0E:5630:0:457=eng:0:0:5003:318:3801:0 > > > > Test results: > > ALPS BSRU6 (old Nova-S) ok > > ALPS BSRU6 (FF rev. 2.1): ok > > Grundig 29504-451 (Activy budget GR) failed [1] > > ALPS BSRV2 (FF rev. 1.3) failed [2] > > > > [1] as expected, tuner supports 12..30 Msymbols/s only > > [2] tuner supports 1..45 Msymbols/s > > > I'm quite sure you will get a lock with the ALPS BSRV2 if you use 5632 > instead of 5630 as the symbol rate. Correct! After spending two evenings for debugging I found that the NIT does not contain the correct symbol rate. vdr automatically adjusted the symbol rate according to the NIT -> 5630. For low symbol rates the ves1893 will lock if (and only if) the symbol rate has been set correctly. 5632 works, 5631/5633 won't. Register programming in the driver appears to be ok. @Klaus: http://www.lyngsat.com/i1002.html specifies SR 6111 for your transponder. Does it work if you change the SR to 6111? Oliver -- -------------------------------------------------------- VDR Remote Plugin available at http://www.escape-edv.de/endriss/vdr/ --------------------------------------------------------