Am Freitag, den 13.02.2015, 17:41 +0100 schrieb Maxime Coquelin: > 2015-02-13 17:25 GMT+01:00 Philipp Zabel <p.zabel@xxxxxxxxxxxxxx>: > > Hi Maxime, > > > > Am Freitag, den 13.02.2015, 16:59 +0100 schrieb Maxime Coquelin: > >> Hi Philipp, > >> > >> 2015-02-13 12:47 GMT+01:00 Philipp Zabel <p.zabel@xxxxxxxxxxxxxx>: > >> > Hi Maxime, > >> > > >> > Am Donnerstag, den 12.02.2015, 18:46 +0100 schrieb Maxime Coquelin: > >> > [...] > >> >> + soc { > >> >> + reset_ahb1: reset@40023810 { > >> >> + #reset-cells = <1>; > >> >> + compatible = "st,stm32-reset"; > >> >> + reg = <0x40023810 0x4>; > >> >> + }; > >> >> + > >> >> + reset_ahb2: reset@40023814 { > >> >> + #reset-cells = <1>; > >> >> + compatible = "st,stm32-reset"; > >> >> + reg = <0x40023814 0x4>; > >> >> + }; > >> >> + > >> >> + reset_ahb3: reset@40023818 { > >> >> + #reset-cells = <1>; > >> >> + compatible = "st,stm32-reset"; > >> >> + reg = <0x40023818 0x4>; > >> >> + }; > >> >> + > >> >> + reset_apb1: reset@40023820 { > >> >> + #reset-cells = <1>; > >> >> + compatible = "st,stm32-reset"; > >> >> + reg = <0x40023820 0x4>; > >> >> + }; > >> >> + > >> >> + reset_apb2: reset@40023824 { > >> >> + #reset-cells = <1>; > >> >> + compatible = "st,stm32-reset"; > >> >> + reg = <0x40023824 0x4>; > >> >> + }; > >> > > >> > These are mostly consecutive, single registers. I wonder if these are > >> > part of the same IP block and thus should be grouped together into the > >> > same reset controller node? > >> > >> What I could to is to have two instances. One for AHB and one for APB domain. > >> Doing this, I will have one instance per domain, and only consecutive registers. > >> Is it fine for you? > > > > Looking at > > http://www.st.com/web/en/resource/technical/document/reference_manual/DM00031020.pdf > > Table 34 (RCC register map and reset values), I'd say there is a single > > "Reset and Clock Control" device at 0x40023800 - 0x40023884: > > > > soc { > > rcc: rcc@40023800 { > > #clock-cells = <1>; > > #reset-cells = <1>; > > compatible = "st,stm32-rcc"; > > reg = <0x40023800 0x84>; > > }; > > > > ... > > > > If you really want to describe the reset controller parts (offsets +0x10 > > to +0x24) in a separate node, I won't argue against it too long, > > although this is a somewhat arbitrary decision. > > > > In any case, the whole register at offset +0x1c is reserved, so there is > > no reason to split the reset controller. It is ok to have unused ranges > > as is already the case with reserved bits inside the used registers. > > Ok. I understand your point. > But it will be more difficult at usage, because the node referencing > the fourth reset bit of apb2 register will have to pass 164 as > parameter. > It is error prone IMHO. > > Other solution would be to add some defines for each reset line in the > DT-Bindings, as we do today for STi platform. > But it is giving an unneeded constraint between DT and reset trees. That is a bit unfortunate, but providing the named constants in include/dt-bindings/reset/ makes for a much better readable device tree, so I'd prefer that solution, even if it means having to coordinate pull requests. regards Philipp -- To unsubscribe from this list: send the line "unsubscribe linux-doc" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html