On Wed, Dec 18, 2013 at 03:11:12AM +0000, Yang, Wenyou wrote: > > This is the wrong type for a voltage table but it looks like it > > shouldn't be a voltage table at all - this looks like it should be > > mapped as linear ranges. > Change it, using unsigned int. > It is not linear, can't be mapped as linear range. so using voltage table. No, linear ranges with a plural - look at regulator_map_voltage_linear_range.