On Intel systems the memory bandwidth monitoring events are independently enumerated. It is possible for a system to support total memory bandwidth monitoring, but not support local bandwidth monitoring. On such a system a user could not enable mba_sc mode. Users will see this highly unhelpful error message from mount: # mount -t resctrl -o mba_MBps resctrl /sys/fs/resctrl mount: /sys/fs/resctrl: wrong fs type, bad option, bad superblock on resctrl, missing codepage or helper program, or other error. dmesg(1) may have more information after failed mount system call. dmesg(1) does not provide any additional information. Modify the existing "mba_MBps" mount option to switch to total bandwidth monitoring if local monitoring is not available. Signed-off-by: Tony Luck <tony.luck@xxxxxxxxx> --- arch/x86/kernel/cpu/resctrl/rdtgroup.c | 2 ++ 1 file changed, 2 insertions(+) diff --git a/arch/x86/kernel/cpu/resctrl/rdtgroup.c b/arch/x86/kernel/cpu/resctrl/rdtgroup.c index 5f64a0b2597c..7410513db45a 100644 --- a/arch/x86/kernel/cpu/resctrl/rdtgroup.c +++ b/arch/x86/kernel/cpu/resctrl/rdtgroup.c @@ -2725,6 +2725,8 @@ static int rdt_parse_param(struct fs_context *fc, struct fs_parameter *param) return -EINVAL; if (is_mbm_local_enabled()) ctx->enable_mba_mbps_local = true; + else if (is_mbm_total_enabled()) + ctx->enable_mba_mbps_total = true; else return -EINVAL; return 0; -- 2.41.0