On Tue, Sep 10, 2013 at 06:44:40PM +0530, Laxman Dewangan wrote: > Here my intention for turn-on time is the time from OFF state to ON > state and the ON voltage settled on this time. > This time is separate from underlying enable time of the device i.e. > will not get added. > We observe in some of platform that some of regulator is taking more > time than time given as per datasheet. > Yes, completely agree that this is not the data provided normally, > just we observe on scope that some of platform shows more than the > datasheet value and hence this patch. So, put this in the binding document then! :P This was more a request to improve the detail in the binding than anything else.