On Thu, Oct 28, 2021 at 10:38:26PM +0800, Zhang Changzhong wrote: > According to SAE-J1939-82 2015 (A.3.6 Row 2), a receiver should never > send TP.CM_CTS to the global address, so we can add a check in > j1939_can_recv() to drop messages with invalid source address. > > Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol") > Signed-off-by: Zhang Changzhong <zhangchangzhong@xxxxxxxxxx> Acked-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx> > --- > net/can/j1939/main.c | 6 ++++++ > 1 file changed, 6 insertions(+) > > diff --git a/net/can/j1939/main.c b/net/can/j1939/main.c > index 9bc55ec..461894e 100644 > --- a/net/can/j1939/main.c > +++ b/net/can/j1939/main.c > @@ -75,6 +75,12 @@ static void j1939_can_recv(struct sk_buff *iskb, void *data) > skcb->addr.pgn = (cf->can_id >> 8) & J1939_PGN_MAX; > /* set default message type */ > skcb->addr.type = J1939_TP; > + if (!j1939_address_is_valid(skcb->addr.sa)) { > + netdev_err_once(priv->ndev, "%s: sa is broadcast address, ignoring!\n", > + __func__); > + goto done; > + } > + > if (j1939_pgn_is_pdu1(skcb->addr.pgn)) { > /* Type 1: with destination address */ > skcb->addr.da = skcb->addr.pgn; > -- > 2.9.5 > > -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |