On 30.09.2021 11:33:20, Zhang Changzhong wrote: > According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so > cancel session when receive unexpected TP.DT message. > > Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol") > Signed-off-by: Zhang Changzhong <zhangchangzhong@xxxxxxxxxx> Applied to linux-can/testing, added stable on Cc. Thanks, Marc -- Pengutronix e.K. | Marc Kleine-Budde | Embedded Linux | https://www.pengutronix.de | Vertretung West/Dortmund | Phone: +49-231-2826-924 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |