Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): cancel session if receive TP.DT with error length

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Thu, Sep 30, 2021 at 11:33:20AM +0800, Zhang Changzhong wrote:
> According to SAE-J1939-21, the data length of TP.DT must be 8 bytes, so
> cancel session when receive unexpected TP.DT message.
> 
> Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
> Signed-off-by: Zhang Changzhong <zhangchangzhong@xxxxxxxxxx>

Acked-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>

Thank you!

> ---
>  net/can/j1939/transport.c | 7 +++++--
>  1 file changed, 5 insertions(+), 2 deletions(-)
> 
> diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
> index bb5c4b8..eedaeaf 100644
> --- a/net/can/j1939/transport.c
> +++ b/net/can/j1939/transport.c
> @@ -1789,6 +1789,7 @@ static void j1939_xtp_rx_dpo(struct j1939_priv *priv, struct sk_buff *skb,
>  static void j1939_xtp_rx_dat_one(struct j1939_session *session,
>  				 struct sk_buff *skb)
>  {
> +	enum j1939_xtp_abort abort = J1939_XTP_ABORT_FAULT;
>  	struct j1939_priv *priv = session->priv;
>  	struct j1939_sk_buff_cb *skcb, *se_skcb;
>  	struct sk_buff *se_skb = NULL;
> @@ -1803,9 +1804,11 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
>  
>  	skcb = j1939_skb_to_cb(skb);
>  	dat = skb->data;
> -	if (skb->len <= 1)
> +	if (skb->len != 8) {
>  		/* makes no sense */
> +		abort = J1939_XTP_ABORT_UNEXPECTED_DATA;
>  		goto out_session_cancel;
> +	}
>  
>  	switch (session->last_cmd) {
>  	case 0xff:
> @@ -1904,7 +1907,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
>   out_session_cancel:
>  	kfree_skb(se_skb);
>  	j1939_session_timers_cancel(session);
> -	j1939_session_cancel(session, J1939_XTP_ABORT_FAULT);
> +	j1939_session_cancel(session, abort);
>  	j1939_session_put(session);
>  }
>  
> -- 
> 2.9.5
> 
> 
> 

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |



[Index of Archives]     [Automotive Discussions]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [IETF Annouce]     [Security]     [Bugtraq]     [Linux]     [Linux OMAP]     [Linux MIPS]     [eCos]     [Asterisk Internet PBX]     [Linux API]     [CAN Bus]

  Powered by Linux