On Mon, May 31, 2021 at 10:47:20AM +0200, Marc Kleine-Budde wrote: > On 26.05.2021 22:33:26, Andy Shevchenko wrote: > > In some configurations, mainly ACPI-based, the clock frequency of the device > > is supplied by very well established 'clock-frequency' property. Hence, try > > to get it from the property at last if no other providers are available. > > return dev_err_probe(&spi->dev, PTR_ERR(reg_xceiver), > > "Failed to get Transceiver regulator!\n"); > > > > - clk = devm_clk_get(&spi->dev, NULL); > > + /* Always ask for fixed clock rate from a property. */ > > + device_property_read_u32(&spi->dev, "clock-frequency", &rate); > > what about error handling....? Not needed, but rate should be assigned to 0, which is missed. > > + clk = devm_clk_get_optional(&spi->dev, NULL); > > if (IS_ERR(clk)) > > return dev_err_probe(&spi->dev, PTR_ERR(clk), > > "Failed to get Oscillator (clock)!\n"); > > freq = clk_get_rate(clk); > > + if (freq == 0) > > + freq = rate; > > ... this means we don't fail if there is neither a clk nor a > clock-frequency property. The following will check for it (which is already in the code) if (freq <= MCP251XFD_SYSCLOCK_HZ_MAX / MCP251XFD_OSC_PLL_MULTIPLIER) { > I've send a v3 to fix this. You mean I have to send v3? Sure! -- With Best Regards, Andy Shevchenko