This patch removes Get-/SetProperties methods along with PropertyChanged signal which are now redundant after moving to generic DBus.Properties interface. --- profiles/thermometer/thermometer.c | 129 +------------------------------------ 1 file changed, 2 insertions(+), 127 deletions(-) diff --git a/profiles/thermometer/thermometer.c b/profiles/thermometer/thermometer.c index b98fe88..cb81da6 100644 --- a/profiles/thermometer/thermometer.c +++ b/profiles/thermometer/thermometer.c @@ -243,9 +243,6 @@ static void change_property(struct thermometer *t, const char *name, return; t->intermediate = *intermediate; - emit_property_changed(device_get_path(t->dev), - THERMOMETER_INTERFACE, name, - DBUS_TYPE_BOOLEAN, &t->intermediate); } else if (g_strcmp0(name, "Interval") == 0) { uint16_t *interval = value; if (t->has_interval && t->interval == *interval) @@ -253,27 +250,18 @@ static void change_property(struct thermometer *t, const char *name, t->has_interval = TRUE; t->interval = *interval; - emit_property_changed(device_get_path(t->dev), - THERMOMETER_INTERFACE, name, - DBUS_TYPE_UINT16, &t->interval); } else if (g_strcmp0(name, "Maximum") == 0) { uint16_t *max = value; if (t->max == *max) return; t->max = *max; - emit_property_changed(device_get_path(t->dev), - THERMOMETER_INTERFACE, name, - DBUS_TYPE_UINT16, &t->max); } else if (g_strcmp0(name, "Minimum") == 0) { uint16_t *min = value; if (t->min == *min) return; t->min = *min; - emit_property_changed(device_get_path(t->dev), - THERMOMETER_INTERFACE, name, - DBUS_TYPE_UINT16, &t->min); } else { DBG("%s is not a thermometer property", name); return; @@ -768,40 +756,6 @@ static void configure_thermometer_cb(GSList *characteristics, guint8 status, } } -static DBusMessage *get_properties(DBusConnection *conn, DBusMessage *msg, - void *data) -{ - struct thermometer *t = data; - DBusMessageIter iter; - DBusMessageIter dict; - DBusMessage *reply; - - reply = dbus_message_new_method_return(msg); - if (reply == NULL) - return NULL; - - dbus_message_iter_init_append(reply, &iter); - - dbus_message_iter_open_container(&iter, DBUS_TYPE_ARRAY, - DBUS_DICT_ENTRY_BEGIN_CHAR_AS_STRING - DBUS_TYPE_STRING_AS_STRING DBUS_TYPE_VARIANT_AS_STRING - DBUS_DICT_ENTRY_END_CHAR_AS_STRING, &dict); - - dict_append_entry(&dict, "Intermediate", DBUS_TYPE_BOOLEAN, - &t->intermediate); - - if (t->has_interval) { - dict_append_entry(&dict, "Interval", DBUS_TYPE_UINT16, - &t->interval); - dict_append_entry(&dict, "Maximum", DBUS_TYPE_UINT16, &t->max); - dict_append_entry(&dict, "Minimum", DBUS_TYPE_UINT16, &t->min); - } - - dbus_message_iter_close_container(&iter, &dict); - - return reply; -} - static void write_interval_cb(guint8 status, const guint8 *pdu, guint16 len, gpointer user_data) { @@ -824,68 +778,6 @@ done: g_free(user_data); } -static DBusMessage *write_attr_interval(struct thermometer *t, DBusMessage *msg, - uint16_t value) -{ - struct tmp_interval_data *data; - uint8_t atval[2]; - - if (t->attrib == NULL) - return btd_error_not_connected(msg); - - if (t->interval_val_handle == 0) - return btd_error_not_available(msg); - - if (value < t->min || value > t->max) - return btd_error_invalid_args(msg); - - att_put_u16(value, &atval[0]); - - data = g_new0(struct tmp_interval_data, 1); - data->thermometer = t; - data->interval = value; - gatt_write_char(t->attrib, t->interval_val_handle, atval, 2, - write_interval_cb, data); - - return dbus_message_new_method_return(msg); -} - -static DBusMessage *set_property(DBusConnection *conn, DBusMessage *msg, - void *data) -{ - struct thermometer *t = data; - const char *property; - DBusMessageIter iter; - DBusMessageIter sub; - uint16_t value; - - if (!dbus_message_iter_init(msg, &iter)) - return btd_error_invalid_args(msg); - - if (dbus_message_iter_get_arg_type(&iter) != DBUS_TYPE_STRING) - return btd_error_invalid_args(msg); - - dbus_message_iter_get_basic(&iter, &property); - if (g_strcmp0("Interval", property) != 0) - return btd_error_invalid_args(msg); - - if (!t->has_interval) - return btd_error_not_available(msg); - - dbus_message_iter_next(&iter); - if (dbus_message_iter_get_arg_type(&iter) != DBUS_TYPE_VARIANT) - return btd_error_invalid_args(msg); - - dbus_message_iter_recurse(&iter, &sub); - - if (dbus_message_iter_get_arg_type(&sub) != DBUS_TYPE_UINT16) - return btd_error_invalid_args(msg); - - dbus_message_iter_get_basic(&sub, &value); - - return write_attr_interval(t, msg, value); -} - static void enable_final_measurement(gpointer data, gpointer user_data) { struct thermometer *t = data; @@ -1227,22 +1119,6 @@ static const GDBusPropertyTable thermometer_properties[] = { { } }; -static const GDBusMethodTable thermometer_methods[] = { - { GDBUS_METHOD("GetProperties", - NULL, GDBUS_ARGS({ "properties", "a{sv}" }), - get_properties) }, - { GDBUS_ASYNC_METHOD("SetProperty", - GDBUS_ARGS({ "name", "s" }, { "value", "v" }), NULL, - set_property) }, - { } -}; - -static const GDBusSignalTable thermometer_signals[] = { - { GDBUS_SIGNAL("PropertyChanged", - GDBUS_ARGS({ "name", "s" }, { "value", "v" })) }, - { } -}; - static void attio_connected_cb(GAttrib *attrib, gpointer user_data) { struct thermometer *t = user_data; @@ -1303,9 +1179,8 @@ int thermometer_register(struct btd_device *device, struct gatt_primary *tattr) if (!g_dbus_register_interface(btd_get_dbus_connection(), path, THERMOMETER_INTERFACE, - thermometer_methods, thermometer_signals, - thermometer_properties, t, - destroy_thermometer)) { + NULL, NULL, thermometer_properties, + t, destroy_thermometer)) { error("D-Bus failed to register %s interface", THERMOMETER_INTERFACE); destroy_thermometer(t); -- 1.8.0 -- To unsubscribe from this list: send the line "unsubscribe linux-bluetooth" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html