Introduce a new binding parameter to thermal trip point description to indicate whether the temperature level specified by the trip point is monitored for a rise or fall in temperature. Signed-off-by: Thara Gopinath <thara.gopinath@xxxxxxxxxx> --- .../devicetree/bindings/thermal/thermal-zones.yaml | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml index 3ec9cc87ec50..cc1332ad6c16 100644 --- a/Documentation/devicetree/bindings/thermal/thermal-zones.yaml +++ b/Documentation/devicetree/bindings/thermal/thermal-zones.yaml @@ -161,6 +161,13 @@ patternProperties: The active trip type can be used to control other HW to help in cooling e.g. fans can be sped up or slowed down + monitor-falling: + description: | + boolean, If true, the trip point is being monitored for + falling temperature. If false/absent/default, the trip + point is being monitored for rising temperature. + type: boolean + required: - temperature - hysteresis -- 2.25.1