This patch adds a new compatible string for sc7180 and also an additional clock listing needed to power the TBUs and the TCU. Signed-off-by: Sharat Masetty <smasetty@xxxxxxxxxxxxxx> --- Documentation/devicetree/bindings/iommu/arm,smmu.yaml | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/Documentation/devicetree/bindings/iommu/arm,smmu.yaml b/Documentation/devicetree/bindings/iommu/arm,smmu.yaml index 6515dbe..15946ac 100644 --- a/Documentation/devicetree/bindings/iommu/arm,smmu.yaml +++ b/Documentation/devicetree/bindings/iommu/arm,smmu.yaml @@ -28,6 +28,7 @@ properties: - enum: - qcom,msm8996-smmu-v2 - qcom,msm8998-smmu-v2 + - qcom,sc7180-smmu-v2 - qcom,sdm845-smmu-v2 - const: qcom,smmu-v2 @@ -113,16 +114,22 @@ properties: present in such cases. clock-names: + minItems: 2 + maxItems: 3 items: - const: bus - const: iface + - const: mem_iface_clk clocks: + minItems: 2 + maxItems: 3 items: - description: bus clock required for downstream bus access and for the smmu ptw - description: interface clock required to access smmu's registers through the TCU's programming interface. + - description: clock required for the SMMU TBUs and the TCU power-domains: maxItems: 1 -- 1.9.1