Re: [RFC PATCH] coresight: dynamic-replicator: Fix handling of multiple connections

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 04/07/2020 12:29 PM, Sai Prakash Ranjan wrote:
Hi Suzuki,

Thanks for looking into this issue.

On 2020-04-07 15:54, Suzuki K Poulose wrote:
On 04/07/2020 10:46 AM, Sai Prakash Ranjan wrote:

There seems to be two replicators back to back here. What is connected
to the other output of both of them ? Are there any TPIUs ? What happens
if you choose a sink on the other end of "swao_replicator" (ETB ?)


The other outport of swao replicator is connected to EUD which is a
QCOM specific HW which can be used as a sink like USB.
And the other outport of other replicator(replicator_out) is connected to
TPIU.

After boot, what do the idfilter registers read for both the replicators ?


Added some prints in replicator_probe.

 replicator probe ret=-517 devname=6046000.replicator idfilter0=0x0 idfilter1=0x0  replicator probe ret=0 devname=6b06000.replicator idfilter0=0xff idfilter1=0xff  replicator probe ret=0 devname=6046000.replicator idfilter0=0xff idfilter1=0xff

Curious to see how the idfilterX is set to 0:
	 if that is never used.
		Or
	 if the user doesn't reset it back to 0xff.

Does your test ever touch EUD (enable the port for EUD at
swao-replicator) ? What are the values before you run your test ?