On Tue, 19 Nov 2019 at 16:46, Niklas Cassel <niklas.cassel@xxxxxxxxxx> wrote: > > CPR (Core Power Reduction) is a technology that reduces core power on a > CPU or other device. It reads voltage settings in efuse from product > test process as initial settings. > Each OPP corresponds to a "corner" that has a range of valid voltages > for a particular frequency. While the device is running at a particular > frequency, CPR monitors dynamic factors such as temperature, etc. and > adjusts the voltage for that frequency accordingly to save power > and meet silicon characteristic requirements. > > This driver is based on an RFC by Stephen Boyd[1], which in turn is > based on work by others on codeaurora.org[2]. > > [1] https://lkml.org/lkml/2015/9/18/833 > [2] https://www.codeaurora.org/cgit/quic/la/kernel/msm-3.10/tree/drivers/regulator/cpr-regulator.c?h=msm-3.10 > > Co-developed-by: Jorge Ramirez-Ortiz <jorge.ramirez-ortiz@xxxxxxxxxx> > Signed-off-by: Jorge Ramirez-Ortiz <jorge.ramirez-ortiz@xxxxxxxxxx> > Signed-off-by: Niklas Cassel <niklas.cassel@xxxxxxxxxx> I have had a look at the genpd provider specific parts. So here are few comments. [...] > + > +struct cpr_drv { > + unsigned int num_corners; > + > + unsigned int ref_clk_khz; > + unsigned int performance_state; Without looking into the details of how this is being used, I assume this reflects the performance state of the genpd provider, which is also tracked by genpd, of course. Could you perhaps make use of an API that gives you the current performance state of the genpd, rather than having to duplicate this? There is patch, reviewed, but not queued yet. https://lore.kernel.org/patchwork/patch/1140368/ > + > + struct generic_pm_domain pd; > + struct device *dev; > + struct mutex lock; > + void __iomem *base; > + struct corner *corner; > + struct regulator *vdd_apc; > + struct clk *cpu_clk; > + struct regmap *tcsr; > + bool loop_disabled; > + u32 gcnt; > + unsigned long flags; > + > + struct fuse_corner *fuse_corners; > + struct corner *corners; > + > + const struct cpr_desc *desc; > + const struct acc_desc *acc_desc; > + const struct cpr_fuse *cpr_fuses; > + > + struct dentry *debugfs; > +}; > + [...] > + > +static int cpr_find_initial_corner(struct cpr_drv *drv) > +{ > + unsigned long rate; > + const struct corner *end; > + struct corner *iter; > + int i = 0; > + > + if (!drv->cpu_clk) { > + dev_err(drv->dev, "cannot get rate from NULL clk\n"); > + return -EINVAL; > + } > + > + end = &drv->corners[drv->num_corners - 1]; > + rate = clk_get_rate(drv->cpu_clk); > + > + for (iter = drv->corners; iter <= end; iter++) { > + if (iter->freq > rate) > + break; > + i++; > + if (iter->freq == rate) { > + drv->corner = iter; > + drv->performance_state = i; > + break; > + } > + if (iter->freq < rate) { > + drv->corner = iter; > + drv->performance_state = i; > + } > + } > + > + if (!drv->corner) { > + dev_err(drv->dev, "boot up corner not found\n"); > + return -EINVAL; > + } > + > + dev_dbg(drv->dev, "boot up perf state: %d\n", i); > + > + return 0; > +} [...] > + > +static int cpr_pd_attach_dev(struct generic_pm_domain *domain, > + struct device *dev) > +{ > + struct cpr_drv *drv = container_of(domain, struct cpr_drv, pd); > + const struct acc_desc *acc_desc = drv->acc_desc; > + int ret; > + > + dev_dbg(drv->dev, "attach callback for: %s\n", dev_name(dev)); > + > + if (drv->cpu_clk) > + return 0; > + > + drv->cpu_clk = devm_clk_get(dev, NULL); > + if (IS_ERR(drv->cpu_clk)) { > + ret = PTR_ERR(drv->cpu_clk); > + if (ret != -EPROBE_DEFER) > + dev_err(drv->dev, "could not get cpu clk: %d\n", ret); > + return ret; > + } I have several thoughts around this.. I understand that you don't want to run the below code more than once per instance of the genpd provider, which seems fine to me. Just to make that clear. However, the above code fetches and stores the clock found from the attached device's OF node, in the cpr driver instance. But, only for the device that is being attached first. I assume this is intentional, but it looks a bit odd. Why isn't the other devices that becomes attached, interesting to fecth/store the clock for? In regards to the clock consumer DT binding, I couldn't find it, but maybe I am not looking at the correct place. Moreover, genpd may run this code in parallel, as the genpd lock isn't being held while invoking the ->attach_dev() callback. This is probably safe anyway, because you don't run dev_pm_domain_attach_by_name(), while attaching the CPU devices, asynchronously. On the other hand, you already have a mutex for the cpr drv, so we might as well use that for protecting against this, don't you think? > + > + dev_dbg(drv->dev, "using cpu clk from: %s\n", dev_name(dev)); > + > + /* > + * Everything related to (virtual) corners has to be initialized > + * here, when attaching to the power domain, since it depends on > + * the power domain's OPP table, which isn't available earlier. > + */ > + drv->num_corners = dev_pm_opp_get_opp_count(&drv->pd.dev); > + if (drv->num_corners < 0) > + return drv->num_corners; > + if (drv->num_corners < 2) { > + dev_err(drv->dev, "need at least 2 OPPs to use CPR\n"); > + return -EINVAL; > + } > + > + dev_dbg(drv->dev, "number of OPPs: %d\n", drv->num_corners); > + > + drv->corners = devm_kcalloc(dev, drv->num_corners, > + sizeof(*drv->corners), > + GFP_KERNEL); > + if (!drv->corners) > + return -ENOMEM; > + > + ret = cpr_corner_init(drv); > + if (ret) > + return ret; > + > + cpr_set_loop_allowed(drv); > + > + ret = cpr_init_parameters(drv); > + if (ret) > + return ret; > + > + /* Configure CPR HW but keep it disabled */ > + ret = cpr_config(drv); > + if (ret) > + return ret; > + > + ret = cpr_find_initial_corner(drv); > + if (ret) > + return ret; > + > + if (acc_desc->config) > + regmap_multi_reg_write(drv->tcsr, acc_desc->config, > + acc_desc->num_regs_per_fuse); > + > + /* Enable ACC if required */ > + if (acc_desc->enable_mask) > + regmap_update_bits(drv->tcsr, acc_desc->enable_reg, > + acc_desc->enable_mask, > + acc_desc->enable_mask); > + > + return 0; > +} [...] > + > +static int cpr_probe(struct platform_device *pdev) > +{ > + struct resource *res; > + struct device *dev = &pdev->dev; > + struct cpr_drv *drv; > + int irq, ret; > + const struct cpr_acc_desc *data; > + struct device_node *np; > + u32 cpr_rev = FUSE_REVISION_UNKNOWN; > + > + data = of_device_get_match_data(dev); > + if (!data || !data->cpr_desc || !data->acc_desc) > + return -EINVAL; > + > + drv = devm_kzalloc(dev, sizeof(*drv), GFP_KERNEL); > + if (!drv) > + return -ENOMEM; > + drv->dev = dev; > + drv->desc = data->cpr_desc; > + drv->acc_desc = data->acc_desc; > + > + drv->fuse_corners = devm_kcalloc(dev, drv->desc->num_fuse_corners, > + sizeof(*drv->fuse_corners), > + GFP_KERNEL); > + if (!drv->fuse_corners) > + return -ENOMEM; > + > + np = of_parse_phandle(dev->of_node, "acc-syscon", 0); > + if (!np) > + return -ENODEV; > + > + drv->tcsr = syscon_node_to_regmap(np); > + of_node_put(np); > + if (IS_ERR(drv->tcsr)) > + return PTR_ERR(drv->tcsr); > + > + mutex_init(&drv->lock); Nitpick, you might as well move this a few lines below, as you may bail out while fetching some of the resources below. > + > + res = platform_get_resource(pdev, IORESOURCE_MEM, 0); > + drv->base = devm_ioremap_resource(dev, res); > + if (IS_ERR(drv->base)) > + return PTR_ERR(drv->base); > + > + irq = platform_get_irq(pdev, 0); > + if (irq < 0) > + return -EINVAL; > + > + drv->vdd_apc = devm_regulator_get(dev, "vdd-apc"); > + if (IS_ERR(drv->vdd_apc)) > + return PTR_ERR(drv->vdd_apc); > + > + /* > + * Initialize fuse corners, since it simply depends > + * on data in efuses. > + * Everything related to (virtual) corners has to be > + * initialized after attaching to the power domain, > + * since is depends on the OPP table. > + */ > + ret = cpr_read_efuse(dev, "cpr_fuse_revision", &cpr_rev); > + if (ret) > + return ret; > + > + drv->cpr_fuses = cpr_get_fuses(drv); > + if (IS_ERR(drv->cpr_fuses)) > + return PTR_ERR(drv->cpr_fuses); > + > + ret = cpr_populate_ring_osc_idx(drv); > + if (ret) > + return ret; > + > + ret = cpr_fuse_corner_init(drv); > + if (ret) > + return ret; > + > + ret = devm_request_threaded_irq(dev, irq, NULL, > + cpr_irq_handler, > + IRQF_ONESHOT | IRQF_TRIGGER_RISING, > + "cpr", drv); > + if (ret) > + return ret; > + > + drv->pd.name = devm_kstrdup_const(dev, dev->of_node->full_name, > + GFP_KERNEL); > + if (!drv->pd.name) > + return -EINVAL; > + > + drv->pd.power_off = cpr_power_off; > + drv->pd.power_on = cpr_power_on; > + drv->pd.set_performance_state = cpr_set_performance; > + drv->pd.opp_to_performance_state = cpr_get_performance; > + drv->pd.attach_dev = cpr_pd_attach_dev; > + > + ret = pm_genpd_init(&drv->pd, NULL, true); > + if (ret) > + return ret; > + > + ret = of_genpd_add_provider_simple(dev->of_node, &drv->pd); > + if (ret) > + return ret; > + > + platform_set_drvdata(pdev, drv); > + cpr_debugfs_init(drv); > + > + return 0; > +} > + > +static int cpr_remove(struct platform_device *pdev) > +{ > + struct cpr_drv *drv = platform_get_drvdata(pdev); > + > + if (cpr_is_allowed(drv)) { > + cpr_ctl_disable(drv); > + cpr_irq_set(drv, 0); > + } > + > + of_genpd_del_provider(pdev->dev.of_node); > + pm_genpd_remove(&drv->pd); > + > + debugfs_remove_recursive(drv->debugfs); > + > + return 0; > +} > + > +static const struct of_device_id cpr_match_table[] = { > + { .compatible = "qcom,qcs404-cpr", .data = &qcs404_cpr_acc_desc }, > + { } > +}; > +MODULE_DEVICE_TABLE(of, cpr_match_table); > + > +static struct platform_driver cpr_driver = { > + .probe = cpr_probe, > + .remove = cpr_remove, > + .driver = { > + .name = "qcom-cpr", > + .of_match_table = cpr_match_table, > + }, > +}; > +module_platform_driver(cpr_driver); > + > +MODULE_DESCRIPTION("Core Power Reduction (CPR) driver"); > +MODULE_LICENSE("GPL v2"); Otherwise this looks good to me. Kind regards Uffe