This will allow calibration routines to correctly include the constants from anywhere and allow more code sharing. Signed-off-by: Amit Kucheria <amit.kucheria@xxxxxxxxxx> --- drivers/thermal/qcom/tsens-common.c | 5 ----- drivers/thermal/qcom/tsens.h | 5 +++++ 2 files changed, 5 insertions(+), 5 deletions(-) diff --git a/drivers/thermal/qcom/tsens-common.c b/drivers/thermal/qcom/tsens-common.c index 92747ccb2850..928e8e81ba69 100644 --- a/drivers/thermal/qcom/tsens-common.c +++ b/drivers/thermal/qcom/tsens-common.c @@ -12,11 +12,6 @@ #include <linux/regmap.h> #include "tsens.h" -#define CAL_DEGC_PT1 30 -#define CAL_DEGC_PT2 120 -#define SLOPE_FACTOR 1000 -#define SLOPE_DEFAULT 3200 - char *qfprom_read(struct device *dev, const char *cname) { struct nvmem_cell *cell; diff --git a/drivers/thermal/qcom/tsens.h b/drivers/thermal/qcom/tsens.h index d648fba235cf..eefe3844fb4e 100644 --- a/drivers/thermal/qcom/tsens.h +++ b/drivers/thermal/qcom/tsens.h @@ -9,6 +9,11 @@ #define ONE_PT_CALIB 0x1 #define ONE_PT_CALIB2 0x2 #define TWO_PT_CALIB 0x3 +#define CAL_DEGC_PT1 30 +#define CAL_DEGC_PT2 120 +#define SLOPE_FACTOR 1000 +#define SLOPE_DEFAULT 3200 + #include <linux/thermal.h> #include <linux/regmap.h> -- 2.17.1