Re: [PATCH v4 2/6] dt-bindings: power: Add qcom rpm power domain driver bindings

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Rob,

[]...
+   rpmhpd_opp_table: opp-table {
+           compatible = "operating-points-v2-qcom-level";
+
+           rpmhpd_opp_ret: opp1 {
+                   qcom,level = <RPMH_REGULATOR_LEVEL_RETENTION>;
+           };

I don't see the point in using the OPP binding here when you aren't
using *any* of the properties from it.

Yeah, that's the case for now. But there are cases (as Stephen
mentioned earlier [1]) where the voltage values (and maybe other
values like current, etc) would be known and filled in DT. And that's
why we all agreed to use OPP tables for PM domains as well, as these
are really "operating performance points" of these PM domains.

Rob, are you fine with these bindings then?

Okay, my only thought is whether we should just use 'reg' here, or do
we need 'level' for anything else and should make it common?

I am not quite sure I understood what you are suggesting here :(