On 8/2/2017 4:27 PM, Bjorn Helgaas wrote: > I haven't worked through all the details of what 6.6.2 says, but I > think it uses 100ms in the context of the *minimum* time software must > wait between initiating an FLR and initializing the function Here is what spec says in 6.6.2 "After an FLR has been initiated by writing a 1b to the Initiate Function Level Reset bit, the Function must complete the FLR within 100 ms." I interpret this as maximum. -- Sinan Kaya Qualcomm Datacenter Technologies, Inc. as an affiliate of Qualcomm Technologies, Inc. Qualcomm Technologies, Inc. is a member of the Code Aurora Forum, a Linux Foundation Collaborative Project. -- To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html