On 20. 06. 2024. 17:01, Chukun Pan wrote:
The mmc controller of the IPQ6018 does not support HS400 mode.
So adjust the maximum clock frequency of sdcc to 200 MHz (HS200).
Signed-off-by: Chukun Pan <amadeus@xxxxxxxxxx>
---
drivers/clk/qcom/gcc-ipq6018.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/qcom/gcc-ipq6018.c b/drivers/clk/qcom/gcc-ipq6018.c
index 7e69de34c310..6c764e3e2665 100644
--- a/drivers/clk/qcom/gcc-ipq6018.c
+++ b/drivers/clk/qcom/gcc-ipq6018.c
@@ -1617,7 +1617,7 @@ static const struct freq_tbl ftbl_sdcc_apps_clk_src[] = {
F(96000000, P_GPLL2, 12, 0, 0),
F(177777778, P_GPLL0, 4.5, 0, 0),
F(192000000, P_GPLL2, 6, 0, 0),
- F(384000000, P_GPLL2, 3, 0, 0),
+ F(200000000, P_GPLL0, 4, 0, 0),
Hi,
Are you sure that 200MHz is even valid of a frequency, cause all IPQ SoC-s
use 192MHz for the HS200 mode instead.
I would just drop the 384MHz frequency as datasheet clearly states that
HS400
is not supported.
Regards,
Robert
{ }
};