On 25/03/2023 13:04, Konrad Dybcio wrote: > > > On 24.03.2023 21:22, Krzysztof Kozlowski wrote: >> The soc node is supposed to have only device nodes with MMIO addresses, >> so move the DSI OPP into the DSI controller node to fix: >> >> sda660-inforce-ifc6560.dtb: soc: opp-table-dsi: {'compatible': ['operating-points-v2'], ... should not be valid under {'type': 'object'} >> From schema: dtschema/schemas/simple-bus.yaml >> >> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> >> --- > Nit: you also changed its node name and didn't mention that, but I > don't see that as anything major so it's gtg as-is Because the binding expect a child named "opp-table", so I assumed it is obvious when you move the table into the device's node. Best regards, Krzysztof