Re: [RFC PATCH 06/10] thermal/drivers/tsens: use generic calibration routine for msm8976

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 12/09/2022 11:57, AngeloGioacchino Del Regno wrote:
Il 10/09/22 14:46, Dmitry Baryshkov ha scritto:
According to msm-3.10, msm8976 uses the same routine for processing
calibration data as other platforms. Drop the msm8976-specific
compute_intercept_slope_8976() and use compute_intercept_slope().

Cc: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxx>
Cc: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>

As far as I remember, at least some MSM8976 versions don't have the slope
fuses populated and/or the values are bad. This is the reason why slopes
are hardcoded.

This commit would break support for MSM8976.
Cc'ing Marijn, as he should be able to re-test this.

Angelo, Marijn, any update on testing this?

--
With best wishes
Dmitry




[Index of Archives]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [Linux for Sparc]     [IETF Annouce]     [Security]     [Bugtraq]     [Linux MIPS]     [ECOS]     [Asterisk Internet PBX]     [Linux API]

  Powered by Linux