Re: [RFC PATCH 06/10] thermal/drivers/tsens: use generic calibration routine for msm8976

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi,

On Mon, 12 Sept 2022 at 11:57, AngeloGioacchino Del Regno
<angelogioacchino.delregno@xxxxxxxxxxxxx> wrote:
>
> Il 10/09/22 14:46, Dmitry Baryshkov ha scritto:
> > According to msm-3.10, msm8976 uses the same routine for processing
> > calibration data as other platforms. Drop the msm8976-specific
> > compute_intercept_slope_8976() and use compute_intercept_slope().
> >
> > Cc: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxx>
> > Cc: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
> > Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>
>
> As far as I remember, at least some MSM8976 versions don't have the slope
> fuses populated and/or the values are bad. This is the reason why slopes
> are hardcoded.
>
> This commit would break support for MSM8976.
> Cc'ing Marijn, as he should be able to re-test this.

Thanks! I was not sure, granted that the downstream seems to use
standard procedure. The details/retesting would be appreciated.


-- 
With best wishes
Dmitry