On 05/07/2022 14:40, Johan Hovold wrote:
The QMP USB PHY provides a single clock so drop the redundant clock
index.
Signed-off-by: Johan Hovold <johan+linaro@xxxxxxxxxx>
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx>
However please note
https://lore.kernel.org/linux-arm-msm/20220620071936.1558906-3-dmitry.baryshkov@xxxxxxxxxx/
(for this and the last patch).
---
arch/arm64/boot/dts/qcom/msm8998.dtsi | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm64/boot/dts/qcom/msm8998.dtsi b/arch/arm64/boot/dts/qcom/msm8998.dtsi
index 758c45bbbe78..2511e70d66ef 100644
--- a/arch/arm64/boot/dts/qcom/msm8998.dtsi
+++ b/arch/arm64/boot/dts/qcom/msm8998.dtsi
@@ -2080,7 +2080,7 @@ usb1_ssphy: phy@c010200 {
<0xc010600 0x128>,
<0xc010800 0x200>;
#phy-cells = <0>;
- #clock-cells = <1>;
+ #clock-cells = <0>;
clocks = <&gcc GCC_USB3_PHY_PIPE_CLK>;
clock-names = "pipe0";
clock-output-names = "usb3_phy_pipe_clk_src";
--
With best wishes
Dmitry