Re: [PATCH v2 1/4] clk: qcom: clk-rcg2: Fail Duty-Cycle configuration if MND divider is not enabled.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Quoting Nikita Travkin (2022-06-12 07:59:52)
> In cases when MND is not enabled (e.g. when only Half Integer Divider is
> used), setting D registers makes no effect.
> 
> Fail instead of making ineffective write.
> 
> Fixes: 7f891faf596e ("clk: qcom: clk-rcg2: Add support for duty-cycle for RCG")
> Signed-off-by: Nikita Travkin <nikita@xxxxxxx>
> ---

Reviewed-by: Stephen Boyd <sboyd@xxxxxxxxxx>