On Fri, 29 Apr 2022 at 17:39, Jassi Brar <jassisinghbrar@xxxxxxxxx> wrote: > > On Fri, Apr 29, 2022 at 6:43 AM Robert Marko <robimarko@xxxxxxxxx> wrote: > > > > IPQ6018 and IPQ8074 require #clock-cells to be set to 1 as their APSS > > clock driver provides multiple clock outputs. > > > > So allow setting 1 as #clock-cells and check that its set to 1 for IPQ6018 > > and IPQ8074, check others for 0 as its currently. > > > Please include qcom specific marker in the subject line. Yeah, I see that I forgot to include the actual binding name. Will fixup in v2. Regards, Robert > > thanks.