On 11/10/11 10:33, David Brown wrote: > On Tue, Nov 08, 2011 at 10:34:02AM -0800, Stephen Boyd wrote: >> Currently the MSM timers use the same physical counter >> for the clockevent and clocksource. This works as long >> as the clocksource isn't stopped from ticking during normal >> operation but unfortunately that isn't the case and the >> clocksource is stopped when the clockevent is shutdown. >> Even worse, switching the clocksource via sysfs at runtime will >> hang the system. >> >> This series reorganizes the MSM timer code so that one counter >> is only used for either a clocksource or a clockevent, and not >> both. In the process we reduce the lines of code and fix >> a few long-standing bugs. > How do you test these on the upstream kernel? Booting successfully is > probably a good starting point, though. > Booting is good because that means you're getting timer interrupts. After that, do some sleep 10, 20, 30, etc. tests with a stopwatch to make sure that time isn't completely off. You can also check bogoMIPS and see what the before and after is. Beyond that I suppose some kind of ntp or gettimeofday test would be good. -- Sent by an employee of the Qualcomm Innovation Center, Inc. The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum. -- To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html