On Fri 2018-11-02 23:57:32, João Paulo Rechi Vita wrote: > Commit 19fffc8450d4378580a8f019b195c4617083176f fixed reporting > "Discharging" on some machines when AC was connected but the battery was > not charging. But now on these machines the battery status is reported > as "Not charging" even when the battery is fully charged. > > This commit takes the battery capacity into consideration when checking > if "Not charging" should be returned and "Full" is returned when the > capacity is 100%. > > Signed-off-by: João Paulo Rechi Vita <jprvita@xxxxxxxxxxxx> We have people trying to modify this and it caused regressions in MATE, IIRC. Plus, I don't think "100% charge" is right test for "battery full". At least on thinkpads, there's configuration option, and it is common _not_ to charge batterry above 95% or so (to increase its lifetime). Pavel > * was plugged in and the device thus did not start a new charge cycle. > */ > if ((battery_ac_is_broken || power_supply_is_system_supplied()) && > - battery->rate_now == 0) > + battery->rate_now == 0) { > + if (battery->capacity_now && battery->full_charge_capacity && > + battery->capacity_now / battery->full_charge_capacity == 1) > + return POWER_SUPPLY_STATUS_FULL; Division? Really? Pavel -- (english) http://www.livejournal.com/~pavelmachek (cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html